Find Jobs
Hire Freelancers

Labview assignment

$10-30 USD

Completed
Posted over 8 years ago

$10-30 USD

Paid on delivery
The required files will be sent to you at the starting of the project. The details are: Control Door Access System Section I: General Requirements The application should: Function as specified in Section II of this document. Conform to LabVIEW coding style and documentation standards Be hierarchical in nature. All major functions should be performed in subVIs. Be easily scalable to add more states / features without having to manually update the hierarchy. Minimize the use of excessive structures, variables (locals / globals) and Property Nodes. Respond to front panel controls (within 100 ms) and not utilize 100% of CPU time. Close all opened references and handles where used. Be well documented and include the following: Labels on appropriate wires within the main VI and subVIs. Descriptions for each algorithm. Documentation in VI Properties » Documentation for both main VI and subVIs. Tip strip and Description for front panel controls and indicators. Labels for constants Section II: Application Requirements Task: Your company has received a contract to design a controller for a door access system. The specifications and rules are listed below. Your job is to design a controller using LabVIEW that satisfies all specifications. Instructions: Using the front panel which is provided, create a LabVIEW application that implements the actions of the procedure specified. For this application, the ID-Card is simulated with the ID-Card cluster. If a user wants to open a door with the ID-Card, the program should check if the user is allowed to enter the room. For easy maintenance of access, the login data is stored in the [login to view URL] provided in the Maintenance folder. It should be possible to add new persons to the Access file without changing the program itself. Example File: NAME SURNAME ACCESS DOOR 1 FROM TO ACCESS DOOR 2 FROM TO Peter Mueller Yes 08:00 17:00 Yes 13:30 19:00 John Smith No X X Yes 14:00 15:00 The Status should show following strings for information: State Message Startup “Please enter your name and choose a picture” Try to open door within correct time, access allowed “Door is now open, please enter the room” Try to open door, access denied “Access denied” Try to open door wrong time “What time is it?? Go Away” Unknown Name “Who are you?” The Access-LED should be “red” in case the door is locked and “green” if the door is open. Every time someone tries to open a door, no matter if it fails or not, the action should logged in the EventLog.txt. Each entry should contain time, date, name, status, door Example File: 20:51:38,748 15.04.2014;Peter;Mueller;Access denied; Door 2 20:51:38,748 15.04.2014;Peter;Mueller;Access denied; Door 1
Project ID: 9213868

About the project

1 proposal
Remote project
Active 8 yrs ago

Looking to make some money?

Benefits of bidding on Freelancer

Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
Awarded to:
User Avatar
Dear client, I have a lot of experience with Labview Send me a message for more information. Looking forward to work with u. Kind regards, Rens Slenders SlenDATA
$40 USD in 3 days
5.0 (1 review)
1.2
1.2

About the client

Flag of GERMANY
Baindt, Germany
5.0
1
Member since Dec 30, 2015

Client Verification

Thanks! We’ve emailed you a link to claim your free credit.
Something went wrong while sending your email. Please try again.
Registered Users Total Jobs Posted
Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)
Copyright © 2024 Freelancer Technology Pty Limited (ACN 142 189 759)
Loading preview
Permission granted for Geolocation.
Your login session has expired and you have been logged out. Please log in again.